Addressable detectors and accessories

DETECTORS

DOD-220A-I | Addressable optical smoke detector with built-in isolator

Properties

Addressable optical smoke detector with built-in isolator, with dirt compensation and algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7 and EN 54-17. Dimensions: 100 x 42 mm.

DOTD-230A-I | Addressable optical & heat detector with built-in isolator

Properties

Addressable optical & heat detector with built-in isolator, with dirt compensation and algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 48 mm.

DTD-210A-I | Addressable heat (58°C fixed temperature and thermal rate of rise) detector with built-in isolator

Properties

Addressable heat (58°C fixed temperature and thermal rate of rise) detector with built-in isolator, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 42 mm.

DTD-215A-I | Addressable high temperature detector (fixed at 78ºC) with built-in isolator

Properties

Addressable high temperature detector (fixed at 78ºC) with built-in isolator, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.

Addressable repeaters - CAD-150 seriesAddressable and standalone gas detectors

RAD-150 | Bidirectional repeater for Detnov addressable CAD-150 series

Properties

Bidirectional repeater for Detnov addressable CAD-150 series. Allows the remote supervision control of control panels networked (F-Network) up to 32 nodes. It shows the same incidences reflected in the control panel. It can be added in ring or bus networks configurations. LCD display and 4 control keys (reset, mute buzzer, mute sounders and activate sounders). Includes RS485 communication card (TRED-150). ABS plastic casing for wall mounting and even prepared to be embedded into it. Requires 230Vac and 2 batteries BTD-1207 (not included). Dimensions: 443 x 268 x 109 mm.

RAD-150 repeater is a complement to any addressable fire alarm installation where there are control panels of the CAD-150 series. Its use is recommended when there is a need for a remote control or visualization of a CAD-150 addressable network with the communication card TRED-150 (F-Network), being able to supervise and manage from a remote-control site. 

 

The repeater incorporates a 4×40 display and can be surface or recessed mounted. The display reproduces all the information that reflects any addressable control panel of the network, allowing us to be informed of the status of all the information. 

 

The keys allow go through the different menus of the repeater, being able to perform actions such as rearming the detection system, silencing it and controlling the alarm devices, such as sounders and flashes, allowing to silence and activate them. 

 

The repeater is considered a node of the network, being able to be connected up to a maximum of 32 devices (addressable control panels CAD-150 and repeaters RAD-150), by means of 2 x 1.5 mm2 shielded cable, there is also the option of fiber optic connection.

RTD-150W | Wireless graphical 7” tablet repeater for addressable CAD-150 series

Properties

Wireless graphical 7” tablet repeater for Detnov addressable CAD-150 series. It allows the visualization and graphic management of the fire detection facility through maps and pictures. Easy and intuitive use. Accepts all picture formats (jpeg, bmp, gif, etc.). Wi-Fi connection is required and at least one RTD-150E or RTD-150T acting as a master device. Dimensions: 188 x 113 x 10 mm. Power supply included.

 

The RTD-150W repeater is a graphic repeater in tablet format for Detnov addressable system.

It allows the visualization and graphical management of fire detection system using its modern and user friendly 7″ touch-screen.

 

It allows connecting to a network of repeaters, using the existing WIFI infrastructure.
Embedded repeater RTD-150E needed to connect the device to the installation.

Addressable and standalone gas detectors

DGD-600-AC | Natural gas detector for residential use and able to be connected to the Detnov addressable loop

Properties

Natural Gas / City Gas (methane) detector for residential use. 230 Vac supply required. Maximum consumption: 65 mA. IP32D. Includes alarm buzzer (85db). Standalone or able to be connected to the Detnov addressable loop. Includes alarm relay and fault relay. Conforms to EN 50194-1. Dimensions: 89.6 x 146.5 x 39 mm. Test button. 3 status LEDs: Service, fault and alarm. Wall mounting or DIN rail.

 

DGD-620-AC | Liquefied petroleum gases (butane and propane) detector for residential use and able to be connected to the Detnov addressable loop

Properties

Liquefied petroleum gases (butane and propane) detector for residential use. 230 Vac supply required. Maximum consumption: 65 mA. IP32D. Includes alarm buzzer (85db). Standalone or able to be connected to the Detnov addressable loop. Includes alarm relay and fault relay. Dimensions: 89.6 x 146.5 x 39 mm. Test button. 3 status LEDs: Service, fault and alarm. Wall mounting or DIN rail.

 

The new 600 series of addressable detectors has been developed for an effective detection of any accidental gas leak of the everyday flammable gases (methane, butane and propane) according to the model.

 

The 600 range of addressable detectors includes 2 detectors powered at 24V (DGD-600 and DGD-620) and 2 detectors powered at 220V (DGD-600-AC and DGD-620-AC).

 

The 600 range of addressable detectors is composed of 4 models: two for the detection of gases lighter than air: natural gas (DGD-600 and DGD-600-AC) and two for the detection of liquefied petroleum gas (LPG): butane and propane (DGD-620 and DGD-620-AC).

 

The detection process for this range is based in the innovate technology of the FIGARO semiconductor sensors and the advanced detection and discrimination algorithms that give a high reliability and accuracy to the 600 series. The alarm levels are 5000 ppm for the natural gas detectors and 2000 ppm for the LPG detectors.

 

The detectors of the 600 range include a fault relay and an alarm relay, 3 LEDs to be able to quickly visualize their status: service, fault and alarm; and a button to perform a test and verify its correct operation. This range of detectors allows its integration into the addressable Detnov system, as well as working autonomously.

Addressable manual call points

MAD-451-I | Addressable manual call point with built-in isolator

Properties

Addressable manual call point with built-in isolator. LED status indicator and test key. Red color. CPR certificates EN54-11 and EN54-17. Dimensions: 85 x 85 x 55 mm.

MAD-450-I | Addressable manual call point with built-in isolator

Properties

Addressable manual call point with built-in isolator. LED status indicator and test key. Red color. CPR certificates EN54-11 and EN54-17. Dimensions: 98 x 98 x 48 mm.

 

STI-13110ESP | Outdoor protector for PCD-100 or MAD-450 manual call points

Properties

Outdoor protector for PCD-100, MAD-450 and MAD-451-I manual call points. Made of hard and transparent polycarbonate. Recommended to avoid vandalism, misuse, situations of involuntary activation of the call point, dust, water and weather indemencies. Includes a seal that seals the unit preventing the entry of dust, dirt and water. IP54. Dimensions: 101 x 126 x18 mm.